Intro
So we got a house with a heat pump, all fine and dandy. I had never had this kind of technology at home, so I knew nothing about it... Then you start using it every day, and you begin to understand how it works and what its behaviour means when you are taking a shower.
At some point in the day you may be in the shower when suddenly COLD WATER gushes down... The hot water tank didn't have time to refill, so the temperature starts to drop. Depending on the shower head in use, the speed at which the heat pump can warm the water may not keep up with how fast the water is being used.
So we learned the tricks, the do's and don'ts. But however well you organise your daily life to use the heat pump the "correct" way, some information will still be missing.
NIBE, the manufacturer of our heat pump, does a good job with the equipment but a very poor job with the user experience. I guess the architecture of the house doesn't take the user into consideration either, as it makes a bad choice on the position of the control.
The problem that needs a solution
When you are getting ready for a shower, you may walk from the living room or the kitchen upstairs and, on the way, glance at the digital display, which gives you some information:

However, taking that peek is not something you will always remember. After all, you want to take a shower; you are not thinking about the details of the system, you want hot water. So when you are already in the shower, or you reach the bathroom by a route that skips the digital display, you still need to know the status of the heat pump.
To solve this, I started a multi-part project (Update: finished in Nov/2026). As I write this I am on the third phase, with one last part still to finish.
The phases
The first phase is to build a way to read information from the heat pump. For that I could use the NIBE developer website: once the heat pump is connected to the internet, I can use their API to read its data.
So I first developed a reader in Golang, which also gives detailed information about the data it extracts from the heat pump.
After this introduction you will find the README from the repository, which I have made public.
The repository is here: https://git.spectronet.org/public-access/nibe-reader
This and the other phases are described in blog entries linked here:
- Part 1: Build a NIBE API reader that uses the myUplink developer website, collects information about the heat pump and shows it on a simple LCD (this blog entry);
- Part 2: Use a script on a Raspberry Pi in the bathroom to show the information on a TFT screen (which also meant soldering the TFT and designing a 3D-printed STL lid for the RPi + TFT);
- Part 3: The most daring and final part: add a humidity sensor and set up an 868 MHz radio transmitter to turn on the ventilation on demand, automatically.
SWOT, the first display (phases 1 and 2)
This is what Part 1 ended up driving: SWOT, a Raspberry Pi with a character LCD in a 3D-printed case, cycling through the heat pump's numbers: water temperature, comfort mode, the reader's own health, and how old the data is.
nibe-reader
Go service that polls the myUplink API for NIBE heat pump data and writes it to local JSON files.
What it does
- Authenticates with myUplink using OAuth2 client credentials
- Fetches all device data points every minute (configurable)
- Saves points as JSON to
logs/points_<systemID>_<deviceID>.json, overwriting on each poll - Saves system/device info once at startup to
logs/systems.json - Renews the auth token every 55 minutes (configurable)
Requirements
- Go 1.24+
- A myUplink developer account with a registered application (client credentials flow)
Register at dev.myuplink.com to get a client ID and secret.
Build
go build -o nibe-reader ./nibe.goConfiguration
All configuration is via environment variables:
| Variable | Required | Default | Description |
|---|---|---|---|
MYUPLINK_CLIENT_ID |
yes | — | OAuth2 client ID |
MYUPLINK_CLIENT_SECRET |
yes | — | OAuth2 client secret |
TOKEN_RENEWAL_INTERVAL_MINUTES |
no | 55 |
Token refresh interval |
DATA_COLLECTION_INTERVAL_MINUTES |
no | 1 |
Points polling interval |
Run
export MYUPLINK_CLIENT_ID=your-client-id
export MYUPLINK_CLIENT_SECRET=your-client-secret
./nibe-readerData is written to logs/ (created automatically).
Utilities
list-parameters
Reads the most recently written points file and prints all available parameter names, IDs, and current values.
go run list-parameters.go
go run list-parameters.go -dir logs -output params.txtlist-parameters results:
# ./list-parameters
Using most recent file: logs/points.json
Available Parameters:
====================
Parameter: - of which hot water:
ID: 44135
Current Value: 3035
Parameter: Average outdoor temp (BT1)
ID: 40067
Current Value: 26
Parameter: Brine in (BT10)
ID: 40015
Current Value: 13.2
Parameter: Brine out (BT11)
ID: 40016
Current Value: 8.4
Parameter: Brine pump speed (GP2)
ID: 43439
Current Value: 100
Parameter: Calculated cooling supply climate system 1
ID: 44270
Current Value: 19.8
Parameter: Calculated supply climate system 1
ID: 43009
Current Value: 20
Parameter: Condenser (BT12)
ID: 40017
Current Value: 53
Parameter: Cooling offset climate system 1
ID: 48739
Current Value: 0
Parameter: Current (BE1)
ID: 40083
Current Value: 0.1
Parameter: Current (BE2)
ID: 40081
Current Value: 0.1
Parameter: Current (BE3)
ID: 40079
Current Value: 0.1
Parameter: Current compressor frequency
ID: 41778
Current Value: 90
Parameter: Current hot water mode
ID: 43109
Current Value: 2
Parameter: Current temperature system 1
ID: 50225
Current Value: -32768
Parameter: Degree minutes
ID: 40941
Current Value: 0
Parameter: Discharge (BT14)
ID: 40018
Current Value: 86.4
Parameter: Est. power at DOT
ID: 42108
Current Value: 3181
Parameter: Extern. adjustment climate system 1
ID: 43161
Current Value: 0
Enum Values:
- 0: Off
- 1: On
Parameter: Extern. blocking input cooling
ID: 43152
Current Value: 0
Enum Values:
- 0: Off
- 1: On
Parameter: Heating medium pump speed (GP1)
ID: 43437
Current Value: 59
Parameter: Hot water amount
ID: 50345
Current Value: 19
Parameter: Hot water boost
ID: 48132
Current Value: 0
Enum Values:
- 0: Off
- 4: One-time incr.
- 1: 3 hr
- 2: 6 hr
- 3: 12 hr
Parameter: Hot water charging (BT6)
ID: 40014
Current Value: 40.5
Parameter: Hot water offset (Smart Price Adaption)
ID: 44897
Current Value: 20
Parameter: Hot water temp.
ID: 50325
Current Value: 49
Parameter: Hot water top (BT7)
ID: 40013
Current Value: 49.2
Parameter: Int elec add heat
ID: 49993
Current Value: 4
Enum Values:
- 0: Alarm
- 1: Alarm
- 2: Active
- 3: Off
- 4: Blocked
- 5: Off
- 6: Active
Parameter: Inverter temperature
ID: 43140
Current Value: 56.8
Parameter: Liquid line (BT15)
ID: 40019
Current Value: 45.9
Parameter: Max compressor frequency
ID: 43123
Current Value: 90
Parameter: Min compressor frequency
ID: 43122
Current Value: 20
Parameter: Next periodic increase: 27 . 05 . 2026
ID: 50249
Current Value: 3
Parameter: Number of compressor starts
ID: 43416
Current Value: 6314
Parameter: Offset
ID: 47011
Current Value: 0
Parameter: Oil temperature (BT29)
ID: 40146
Current Value: 0
Parameter: Oil temperature (EP15-BT29)
ID: 40145
Current Value: 0
Parameter: Oper. time
ID: 43420
Current Value: 17226
Parameter: Oper. time hot water
ID: 43424
Current Value: 3035
Parameter: Outdoor temperature
ID: 40004
Current Value: 25
Parameter: Power internal add. heat
ID: 43084
Current Value: 0
Parameter: Priority
ID: 49994
Current Value: 20
Enum Values:
- 10: Off
- 20: Hot water
- 30: Heating
- 40: Pool
- 41: Pool 2
- 50: Transfer
- 60: Cooling
Parameter: Pump: Brine (GP2)
ID: 50203
Current Value: 1
Enum Values:
- 0: Off
- 1: On
Parameter: Pump: Heating medium (GP1)
ID: 49995
Current Value: 1
Enum Values:
- 0: Off
- 1: On
Parameter: Return line (BT3)
ID: 40012
Current Value: 45.7
Parameter: Room sensor set point value cooling climate system 1
ID: 48785
Current Value: 26
Parameter: Room sensor set point value heating climate system 1
ID: 47398
Current Value: 22
Parameter: Room temperature (BT50)
ID: 40033
Current Value: 26.2
Parameter: Set point value temp system 1, cooling
ID: 50241
Current Value: 0
Parameter: Set point value temp system 1, heat
ID: 50233
Current Value: -32768
Parameter: Smart Control
ID: 50320
Current Value: 0
Enum Values:
- 0: off
- 1: on
Parameter: Status compressor
ID: 43427
Current Value: 60
Enum Values:
- 20: Off
- 40: Starting
- 60: Operating
- 100: Stopping
Parameter: Suction gas (BT17)
ID: 40022
Current Value: 15.9
Parameter: Supply line (BT2)
ID: 40008
Current Value: 52.5
Parameter: Temporary lux
ID: 50004
Current Value: 0
Enum Values:
- 0: off
- 1: on
Parameter: Text not found: id[], fw[nibe-e10], lang[en-US]
ID: 65535
Current Value: 0
Parameter: Time factor add heat
ID: 43081
Current Value: 542.5
Parameter: Used power at DOT
ID: 45434
Current Value: 3181
Parameter: activated
ID: 48442
Current Value: 0
Parameter: alarm room sens cool
ID: 49903
Current Value: 1
Parameter: change in curve
ID: 47028
Current Value: 0
Parameter: climate system
ID: 49715
Current Value: 20
Parameter: comfort mode
ID: 47041
Current Value: 4
Enum Values:
- 0: 0
Parameter: control room sensor syst
ID: 47394
Current Value: 1
Parameter: cool at room over temp.
ID: 47337
Current Value: 2
Parameter: cool/heat sensor
ID: 47340
Current Value: 10
Enum Values:
- 0: none
- 2: BT50
- 10: RMU-BT50
Parameter: cooling curve
ID: 48731
Current Value: 0
Parameter: cooling factor system
ID: 48793
Current Value: 1
Parameter: current value
ID: 40940
Current Value: 0
Parameter: dT Inverter - exh air (BT20)
ID: 43146
Current Value: 0
Parameter: diff. between additional steps
ID: 47209
Current Value: 100
Parameter: filtering time
ID: 47377
Current Value: 2
Parameter: flow line temp. at -10 °C
ID: 47024
Current Value: 35
Parameter: flow line temp. at -20 °C
ID: 47025
Current Value: 40
Parameter: flow line temp. at -30 °C
ID: 47026
Current Value: 45
Parameter: flow line temp. at 0 °C
ID: 48742
Current Value: 20
Parameter: flow line temp. at 10 °C
ID: 48741
Current Value: 20
Parameter: flow line temp. at 20 °C
ID: 48181
Current Value: 20
Parameter: flow line temp. at 30 °C
ID: 48740
Current Value: 20
Parameter: flow line temp. at 40 °C
ID: 48185
Current Value: 20
Parameter: heat at room under temp.
ID: 47336
Current Value: 1
Parameter: heating curve
ID: 47007
Current Value: 6
Parameter: heating factor system
ID: 47402
Current Value: 2
Parameter: number of starts:
ID: 44131
Current Value: 6314
Parameter: op. mode
ID: 47137
Current Value: 0
Enum Values:
- 0: auto
- 1: manual
- 2: add. heat only
Parameter: outdoor temp. point
ID: 47027
Current Value: 0
Parameter: period
ID: 47051
Current Value: 15
Parameter: set max electrical add.
ID: 47212
Current Value: 500
Enum Values:
- 0: 0.0 kW
- 50: 0.50 kW
- 100: 1.0 kW
- 150: 1.50 kW
- 200: 2.0 kW
- 250: 2.50 kW
- 300: 3.0 kW
- 350: 3.50 kW
- 400: 4.0 kW
- 450: 4.50 kW
- 500: 5.0 kW
- 550: 5.50 kW
- 600: 6.0 kW
- 650: 6.50 kW
Parameter: set pt value cool/heat sensor
ID: 48074
Current Value: 21
Parameter: start compressor
ID: 47206
Current Value: -60
Parameter: start cooling
ID: 47374
Current Value: 25
Parameter: start diff additional heat
ID: 48072
Current Value: 400
Parameter: start time
ID: 49909
Current Value: 0
Parameter: status:
ID: 50113
Current Value: 1512
Enum Values:
- 15000: Starting
- 15001: Operating
- 15002: Stopping
- 15003: Off
- 15004: Hot water
- 15005: Heating
- 15006: Pool
- 15007: Cooling
- 15008: Transfer
- 10480: incomp. hp
- 10065: Comm.fault In
- 10066: Communication fault with PCA Input.
- 10067: Communication fault with PCA Input.
- 10068: Com.flt Base
- 10069: Communication fault with PCA Base.
- 10070: Communication fault with PCA Base.
- 10162: Sens flt:BT18
- 15971: incomp. inv.
- 10177: Sens flt:BT14
- 10071: HP alarm
- 10072: High pressure alarm
- 10073: High pressure alarm
- 10074: LP alarm
- 10075: Low pressure alarm
- 10076: Low pressure alarm
- 10077: Comm.flt MC
- 10078: Comm.flt with PCA Motor Controller
- 10079: Communication fault with PCA Motor Controller.
- 10080: MP alarm
- 10081: Motor protection alarm
- 10082: Motor protection alarm
- 10083: Sensor flt:BT1
- 10084: Sensor fault: BT1 outdoor sensor
- 10085: Sensor fault: BT1 outdoor sensor
- 10086: Sensor flt:BT2
- 10087: Sensor fault: BT2 flow line sensor 1
- 10088: Sensor fault: BT2 flow line sensor 1
- 10089: Sens flt:BT12
- 10090: Sensor fault: BT12 condenser out
- 10091: Sensor fault: BT12 condenser out
- 10092: Sensor flt:BT3
- 10095: Sensor flt:BT6
- 10154: internal electrical addition
- 10183: L exh.temp
- 10203: Sensor flt:BT7
- 10187: Defrosting
- 15117: blocked
- 16528: Inverter fault
- 10068: Com.flt Base
- 10311: Inverter I
- 10314: Inverter II
- 10317: Inverter III
- 10110: Hot gas alarm
- 10116: TB alarm
- 10122: Hi cond. out
- 10276: Err: BT63
- 10293: serial no
- 10296: software
- 11176: comm.err hp
- 15117: blocked
- 15629: ext control
- 15701: Preheat
- 15966: Pres.alarm
- 15971: incomp. inv.
- 16537: Soft-start flt
- 16659: Acc. block.
- 15468: initiating
- 11165: pool 2
- 11174: com.err.slave
- 15985: Com.flt GP12
- 16541: not docked
Parameter: stop additional heat
ID: 47376
Current Value: 2
Parameter: stop heating
ID: 47375
Current Value: 20
Parameter: time betw. switch heat/cool
ID: 47335
Current Value: 2
Parameter: total operating time:
ID: 44133
Current Value: 17226Log points file:
# cat points.json
[
{
"category": "F1255-6 R PC",
"parameterId": "40004",
"parameterName": "Outdoor temperature",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T16:59:19+00:00",
"value": 25.0,
"strVal": "25°C",
"smartHomeCategories": [
"sh-outdoorTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40008",
"parameterName": "Supply line (BT2)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:33+00:00",
"value": 52.5,
"strVal": "52.5°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40012",
"parameterName": "Return line (BT3)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:31+00:00",
"value": 45.7,
"strVal": "45.7°C",
"smartHomeCategories": [
"sh-returnTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40013",
"parameterName": "Hot water top (BT7)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:04:04+00:00",
"value": 49.2,
"strVal": "49.2°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40014",
"parameterName": "Hot water charging (BT6)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:37+00:00",
"value": 40.5,
"strVal": "40.5°C",
"smartHomeCategories": [
"sh-hwTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40015",
"parameterName": "Brine in (BT10)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T12:44:39+00:00",
"value": 13.2,
"strVal": "13.2°C",
"smartHomeCategories": [
"sh-returnTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40016",
"parameterName": "Brine out (BT11)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:13:20+00:00",
"value": 8.4,
"strVal": "8.4°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40017",
"parameterName": "Condenser (BT12)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:07+00:00",
"value": 53.0,
"strVal": "53°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40018",
"parameterName": "Discharge (BT14)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:45+00:00",
"value": 86.4,
"strVal": "86.4°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40019",
"parameterName": "Liquid line (BT15)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:43+00:00",
"value": 45.9,
"strVal": "45.9°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40022",
"parameterName": "Suction gas (BT17)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:13:42+00:00",
"value": 15.9,
"strVal": "15.9°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40033",
"parameterName": "Room temperature (BT50)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T15:23:37+00:00",
"value": 26.2,
"strVal": "26.2°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40067",
"parameterName": "Average outdoor temp (BT1)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:16+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40079",
"parameterName": "Current (BE3)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40081",
"parameterName": "Current (BE2)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40083",
"parameterName": "Current (BE1)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40145",
"parameterName": "Oil temperature (EP15-BT29)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40146",
"parameterName": "Oil temperature (BT29)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40940",
"parameterName": "current value",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-05-24T06:09:02+00:00",
"value": 0.0,
"strVal": "0DM",
"smartHomeCategories": [],
"minValue": -3000.0,
"maxValue": 3000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40941",
"parameterName": "Degree minutes",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T06:09:02+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "41778",
"parameterName": "Current compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-05-24T17:11:28+00:00",
"value": 90.0,
"strVal": "90Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "42108",
"parameterName": "Est. power at DOT",
"parameterUnit": "W",
"writable": false,
"timestamp": "2026-05-22T16:25:44+00:00",
"value": 3181.0,
"strVal": "3181W",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43009",
"parameterName": "Calculated supply climate system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-22T04:52:47+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43081",
"parameterName": "Time factor add heat",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-23T18:00:40+00:00",
"value": 542.5,
"strVal": "542.5",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43084",
"parameterName": "Power internal add. heat",
"parameterUnit": "kW",
"writable": false,
"timestamp": "2026-05-23T18:06:04+00:00",
"value": 0.0,
"strVal": "0kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.01,
"enumValues": [],
"scaleValue": "0.01",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43109",
"parameterName": "Current hot water mode",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 2.0,
"strVal": "2",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43122",
"parameterName": "Min compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 20.0,
"strVal": "20Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43123",
"parameterName": "Max compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-05-24T17:03:23+00:00",
"value": 90.0,
"strVal": "90Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43140",
"parameterName": "Inverter temperature",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:33+00:00",
"value": 56.8,
"strVal": "56.8°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43146",
"parameterName": "dT Inverter - exh air (BT20)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "Built-in pass. cooling",
"parameterId": "43152",
"parameterName": "Extern. blocking input cooling",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43161",
"parameterName": "Extern. adjustment climate system 1",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43239",
"parameterName": "- of which hot water:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-23T18:05:00+00:00",
"value": 500.0,
"strVal": "500hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43416",
"parameterName": "Number of compressor starts",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:21+00:00",
"value": 6314.0,
"strVal": "6314",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43420",
"parameterName": "Oper. time",
"parameterUnit": "h",
"writable": false,
"timestamp": "2026-05-24T17:11:34+00:00",
"value": 17226.0,
"strVal": "17226h",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43424",
"parameterName": "Oper. time hot water",
"parameterUnit": "h",
"writable": false,
"timestamp": "2026-05-23T17:27:51+00:00",
"value": 3035.0,
"strVal": "3035h",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43427",
"parameterName": "Status compressor",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:21+00:00",
"value": 60.0,
"strVal": "Operating",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "20",
"text": "Off",
"icon": ""
},
{
"value": "40",
"text": "Starting",
"icon": ""
},
{
"value": "60",
"text": "Operating",
"icon": ""
},
{
"value": "100",
"text": "Stopping",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43437",
"parameterName": "Heating medium pump speed (GP1)",
"parameterUnit": "%",
"writable": false,
"timestamp": "2026-05-24T17:11:08+00:00",
"value": 59.0,
"strVal": "59%",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43439",
"parameterName": "Brine pump speed (GP2)",
"parameterUnit": "%",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 100.0,
"strVal": "100%",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44131",
"parameterName": "number of starts:",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:22+00:00",
"value": 6314.0,
"strVal": "6314",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44133",
"parameterName": "total operating time:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-24T17:11:35+00:00",
"value": 17226.0,
"strVal": "17226hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44135",
"parameterName": "- of which hot water:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-23T17:27:52+00:00",
"value": 3035.0,
"strVal": "3035hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "Built-in pass. cooling",
"parameterId": "44270",
"parameterName": "Calculated cooling supply climate system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T16:36:35+00:00",
"value": 19.8,
"strVal": "19.8°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44897",
"parameterName": "Hot water offset (Smart Price Adaption)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 20.0,
"strVal": "20",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "45434",
"parameterName": "Used power at DOT",
"parameterUnit": "W",
"writable": false,
"timestamp": "2026-05-23T18:06:38+00:00",
"value": 3181.0,
"strVal": "3181W",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47007",
"parameterName": "heating curve",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 6.0,
"strVal": "6",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 15.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47011",
"parameterName": "Offset",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47015",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 70.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47020",
"parameterName": "flow line temp. at 30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47021",
"parameterName": "flow line temp. at 20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47022",
"parameterName": "flow line temp. at 10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47023",
"parameterName": "flow line temp. at 0 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 32.0,
"strVal": "32°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47024",
"parameterName": "flow line temp. at -10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 35.0,
"strVal": "35°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47025",
"parameterName": "flow line temp. at -20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 40.0,
"strVal": "40°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47026",
"parameterName": "flow line temp. at -30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 45.0,
"strVal": "45°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47027",
"parameterName": "outdoor temp. point",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": -40.0,
"maxValue": 30.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47028",
"parameterName": "change in curve",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47036",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 30.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47041",
"parameterName": "comfort mode",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 4.0,
"strVal": "4",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "0",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47050",
"parameterName": "activated",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47051",
"parameterName": "period",
"parameterUnit": "days",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15days",
"smartHomeCategories": [],
"minValue": 1.0,
"maxValue": 90.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47137",
"parameterName": "op. mode",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:31+00:00",
"value": 0.0,
"strVal": "auto",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "auto",
"icon": ""
},
{
"value": "1",
"text": "manual",
"icon": ""
},
{
"value": "2",
"text": "add. heat only",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47206",
"parameterName": "start compressor",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -60.0,
"strVal": "-60DM",
"smartHomeCategories": [],
"minValue": -1000.0,
"maxValue": -30.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47209",
"parameterName": "diff. between additional steps",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 100.0,
"strVal": "100DM",
"smartHomeCategories": [],
"minValue": 10.0,
"maxValue": 1000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47212",
"parameterName": "set max electrical add.",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:31+00:00",
"value": 500.0,
"strVal": "5.0 kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "0.0 kW",
"icon": ""
},
{
"value": "50",
"text": "0.50 kW",
"icon": ""
},
{
"value": "100",
"text": "1.0 kW",
"icon": ""
},
{
"value": "150",
"text": "1.50 kW",
"icon": ""
},
{
"value": "200",
"text": "2.0 kW",
"icon": ""
},
{
"value": "250",
"text": "2.50 kW",
"icon": ""
},
{
"value": "300",
"text": "3.0 kW",
"icon": ""
},
{
"value": "350",
"text": "3.50 kW",
"icon": ""
},
{
"value": "400",
"text": "4.0 kW",
"icon": ""
},
{
"value": "450",
"text": "4.50 kW",
"icon": ""
},
{
"value": "500",
"text": "5.0 kW",
"icon": ""
},
{
"value": "550",
"text": "5.50 kW",
"icon": ""
},
{
"value": "600",
"text": "6.0 kW",
"icon": ""
},
{
"value": "650",
"text": "6.50 kW",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47335",
"parameterName": "time betw. switch heat/cool",
"parameterUnit": "hrs",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2hrs",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 48.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47336",
"parameterName": "heat at room under temp.",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1°C",
"smartHomeCategories": [],
"minValue": 0.5,
"maxValue": 10.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47337",
"parameterName": "cool at room over temp.",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2°C",
"smartHomeCategories": [],
"minValue": 0.5,
"maxValue": 10.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47340",
"parameterName": "cool/heat sensor",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 10.0,
"strVal": "RMU-BT50",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "none",
"icon": ""
},
{
"value": "2",
"text": "BT50",
"icon": ""
},
{
"value": "10",
"text": "RMU-BT50",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47374",
"parameterName": "start cooling",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 25.0,
"strVal": "25°C",
"smartHomeCategories": [],
"minValue": -20.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47375",
"parameterName": "stop heating",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -20.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47376",
"parameterName": "stop additional heat",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2°C",
"smartHomeCategories": [],
"minValue": -25.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47377",
"parameterName": "filtering time",
"parameterUnit": "hrs",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2hrs",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 48.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47394",
"parameterName": "control room sensor syst",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47398",
"parameterName": "Room sensor set point value heating climate system 1",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 22.0,
"strVal": "22°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 35.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47402",
"parameterName": "heating factor system",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 6.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48072",
"parameterName": "start diff additional heat",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 400.0,
"strVal": "400DM",
"smartHomeCategories": [],
"minValue": 100.0,
"maxValue": 2000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48074",
"parameterName": "set pt value cool/heat sensor",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 21.0,
"strVal": "21°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48132",
"parameterName": "Hot water boost",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-04-02T15:19:09+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [
"sh-hwBoost"
],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "4",
"text": "One-time incr.",
"icon": ""
},
{
"value": "1",
"text": "3 hr",
"icon": ""
},
{
"value": "2",
"text": "6 hr",
"icon": ""
},
{
"value": "3",
"text": "12 hr",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48177",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 18.0,
"strVal": "18°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 30.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48181",
"parameterName": "flow line temp. at 20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48185",
"parameterName": "flow line temp. at 40 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48442",
"parameterName": "activated",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T13:11:03+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48731",
"parameterName": "cooling curve",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 9.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48739",
"parameterName": "Cooling offset climate system 1",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48740",
"parameterName": "flow line temp. at 30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48741",
"parameterName": "flow line temp. at 10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48742",
"parameterName": "flow line temp. at 0 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48785",
"parameterName": "Room sensor set point value cooling climate system 1",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 35.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48793",
"parameterName": "cooling factor system",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 6.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49715",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 30.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49903",
"parameterName": "alarm room sens cool",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49909",
"parameterName": "start time",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 23.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49993",
"parameterName": "Int elec add heat",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-23T18:06:01+00:00",
"value": 4.0,
"strVal": "Blocked",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Alarm",
"icon": ""
},
{
"value": "1",
"text": "Alarm",
"icon": ""
},
{
"value": "2",
"text": "Active",
"icon": ""
},
{
"value": "3",
"text": "Off",
"icon": ""
},
{
"value": "4",
"text": "Blocked",
"icon": ""
},
{
"value": "5",
"text": "Off",
"icon": ""
},
{
"value": "6",
"text": "Active",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49994",
"parameterName": "Priority",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:01+00:00",
"value": 20.0,
"strVal": "Hot water",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "10",
"text": "Off",
"icon": ""
},
{
"value": "20",
"text": "Hot water",
"icon": ""
},
{
"value": "30",
"text": "Heating",
"icon": ""
},
{
"value": "40",
"text": "Pool",
"icon": ""
},
{
"value": "41",
"text": "Pool 2",
"icon": ""
},
{
"value": "50",
"text": "Transfer",
"icon": ""
},
{
"value": "60",
"text": "Cooling",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49995",
"parameterName": "Pump: Heating medium (GP1)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T08:09:14+00:00",
"value": 1.0,
"strVal": "On",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50004",
"parameterName": "Temporary lux",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "off",
"icon": ""
},
{
"value": "1",
"text": "on",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50095",
"parameterName": "status:",
"parameterUnit": "min",
"writable": false,
"timestamp": "2026-05-24T17:00:33+00:00",
"value": 15004.0,
"strVal": "15004min",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "15000",
"text": "Starting",
"icon": ""
},
{
"value": "15001",
"text": "Operating",
"icon": ""
},
{
"value": "15002",
"text": "Stopping",
"icon": ""
},
{
"value": "15003",
"text": "Off",
"icon": ""
},
{
"value": "15004",
"text": "Hot water",
"icon": ""
},
{
"value": "15005",
"text": "Heating",
"icon": ""
},
{
"value": "15006",
"text": "Pool",
"icon": ""
},
{
"value": "15007",
"text": "Cooling",
"icon": ""
},
{
"value": "15008",
"text": "Transfer",
"icon": ""
},
{
"value": "10480",
"text": "incomp. hp",
"icon": ""
},
{
"value": "10065",
"text": "Comm.fault In",
"icon": ""
},
{
"value": "10066",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10067",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10069",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10070",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10162",
"text": "Sens flt:BT18",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "10177",
"text": "Sens flt:BT14",
"icon": ""
},
{
"value": "10071",
"text": "HP alarm",
"icon": ""
},
{
"value": "10072",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10073",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10074",
"text": "LP alarm",
"icon": ""
},
{
"value": "10075",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10076",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10077",
"text": "Comm.flt MC",
"icon": ""
},
{
"value": "10078",
"text": "Comm.flt with PCA Motor Controller",
"icon": ""
},
{
"value": "10079",
"text": "Communication fault with PCA Motor Controller.",
"icon": ""
},
{
"value": "10080",
"text": "MP alarm",
"icon": ""
},
{
"value": "10081",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10082",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10083",
"text": "Sensor flt:BT1",
"icon": ""
},
{
"value": "10084",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10085",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10086",
"text": "Sensor flt:BT2",
"icon": ""
},
{
"value": "10087",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10088",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10089",
"text": "Sens flt:BT12",
"icon": ""
},
{
"value": "10090",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10091",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10092",
"text": "Sensor flt:BT3",
"icon": ""
},
{
"value": "10095",
"text": "Sensor flt:BT6",
"icon": ""
},
{
"value": "10154",
"text": "internal electrical addition",
"icon": ""
},
{
"value": "10183",
"text": "L exh.temp",
"icon": ""
},
{
"value": "10203",
"text": "Sensor flt:BT7",
"icon": ""
},
{
"value": "10187",
"text": "Defrosting",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "16528",
"text": "Inverter fault",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10311",
"text": "Inverter I",
"icon": ""
},
{
"value": "10314",
"text": "Inverter II",
"icon": ""
},
{
"value": "10317",
"text": "Inverter III",
"icon": ""
},
{
"value": "10110",
"text": "Hot gas alarm",
"icon": ""
},
{
"value": "10116",
"text": "TB alarm",
"icon": ""
},
{
"value": "10122",
"text": "Hi cond. out",
"icon": ""
},
{
"value": "10276",
"text": "Err: BT63",
"icon": ""
},
{
"value": "10293",
"text": "serial no",
"icon": ""
},
{
"value": "10296",
"text": "software",
"icon": ""
},
{
"value": "11176",
"text": "comm.err hp",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "15629",
"text": "ext control",
"icon": ""
},
{
"value": "15701",
"text": "Preheat",
"icon": ""
},
{
"value": "15966",
"text": "Pres.alarm",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "16537",
"text": "Soft-start flt",
"icon": ""
},
{
"value": "16659",
"text": "Acc. block.",
"icon": ""
},
{
"value": "15468",
"text": "initiating",
"icon": ""
},
{
"value": "11165",
"text": "pool 2",
"icon": ""
},
{
"value": "11174",
"text": "com.err.slave",
"icon": ""
},
{
"value": "15985",
"text": "Com.flt GP12",
"icon": ""
},
{
"value": "16541",
"text": "not docked",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50113",
"parameterName": "status:",
"parameterUnit": "kW",
"writable": false,
"timestamp": "2026-05-23T18:06:03+00:00",
"value": 1512.0,
"strVal": "1512kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [
{
"value": "15000",
"text": "Starting",
"icon": ""
},
{
"value": "15001",
"text": "Operating",
"icon": ""
},
{
"value": "15002",
"text": "Stopping",
"icon": ""
},
{
"value": "15003",
"text": "Off",
"icon": ""
},
{
"value": "15004",
"text": "Hot water",
"icon": ""
},
{
"value": "15005",
"text": "Heating",
"icon": ""
},
{
"value": "15006",
"text": "Pool",
"icon": ""
},
{
"value": "15007",
"text": "Cooling",
"icon": ""
},
{
"value": "15008",
"text": "Transfer",
"icon": ""
},
{
"value": "10480",
"text": "incomp. hp",
"icon": ""
},
{
"value": "10065",
"text": "Comm.fault In",
"icon": ""
},
{
"value": "10066",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10067",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10069",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10070",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10162",
"text": "Sens flt:BT18",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "10177",
"text": "Sens flt:BT14",
"icon": ""
},
{
"value": "10071",
"text": "HP alarm",
"icon": ""
},
{
"value": "10072",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10073",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10074",
"text": "LP alarm",
"icon": ""
},
{
"value": "10075",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10076",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10077",
"text": "Comm.flt MC",
"icon": ""
},
{
"value": "10078",
"text": "Comm.flt with PCA Motor Controller",
"icon": ""
},
{
"value": "10079",
"text": "Communication fault with PCA Motor Controller.",
"icon": ""
},
{
"value": "10080",
"text": "MP alarm",
"icon": ""
},
{
"value": "10081",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10082",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10083",
"text": "Sensor flt:BT1",
"icon": ""
},
{
"value": "10084",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10085",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10086",
"text": "Sensor flt:BT2",
"icon": ""
},
{
"value": "10087",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10088",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10089",
"text": "Sens flt:BT12",
"icon": ""
},
{
"value": "10090",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10091",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10092",
"text": "Sensor flt:BT3",
"icon": ""
},
{
"value": "10095",
"text": "Sensor flt:BT6",
"icon": ""
},
{
"value": "10154",
"text": "internal electrical addition",
"icon": ""
},
{
"value": "10183",
"text": "L exh.temp",
"icon": ""
},
{
"value": "10203",
"text": "Sensor flt:BT7",
"icon": ""
},
{
"value": "10187",
"text": "Defrosting",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "16528",
"text": "Inverter fault",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10311",
"text": "Inverter I",
"icon": ""
},
{
"value": "10314",
"text": "Inverter II",
"icon": ""
},
{
"value": "10317",
"text": "Inverter III",
"icon": ""
},
{
"value": "10110",
"text": "Hot gas alarm",
"icon": ""
},
{
"value": "10116",
"text": "TB alarm",
"icon": ""
},
{
"value": "10122",
"text": "Hi cond. out",
"icon": ""
},
{
"value": "10276",
"text": "Err: BT63",
"icon": ""
},
{
"value": "10293",
"text": "serial no",
"icon": ""
},
{
"value": "10296",
"text": "software",
"icon": ""
},
{
"value": "11176",
"text": "comm.err hp",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "15629",
"text": "ext control",
"icon": ""
},
{
"value": "15701",
"text": "Preheat",
"icon": ""
},
{
"value": "15966",
"text": "Pres.alarm",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "16537",
"text": "Soft-start flt",
"icon": ""
},
{
"value": "16659",
"text": "Acc. block.",
"icon": ""
},
{
"value": "15468",
"text": "initiating",
"icon": ""
},
{
"value": "11165",
"text": "pool 2",
"icon": ""
},
{
"value": "11174",
"text": "com.err.slave",
"icon": ""
},
{
"value": "15985",
"text": "Com.flt GP12",
"icon": ""
},
{
"value": "16541",
"text": "not docked",
"icon": ""
}
],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50203",
"parameterName": "Pump: Brine (GP2)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T08:09:13+00:00",
"value": 1.0,
"strVal": "On",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50225",
"parameterName": "Current temperature system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -32768.0,
"strVal": "-32768°C",
"smartHomeCategories": [
"sh-indoorTempOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50233",
"parameterName": "Set point value temp system 1, heat",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -32768.0,
"strVal": "-32768°C",
"smartHomeCategories": [
"sh-indoorSpHeatOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50241",
"parameterName": "Set point value temp system 1, cooling",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [
"sh-indoorSpCoolOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50249",
"parameterName": "Next periodic increase: 27 . 05 . 2026",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-12T17:17:37+00:00",
"value": 3.0,
"strVal": "3",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50320",
"parameterName": "Smart Control",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "off",
"icon": ""
},
{
"value": "1",
"text": "on",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50325",
"parameterName": "Hot water temp.",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:16+00:00",
"value": 49.0,
"strVal": "49°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50345",
"parameterName": "Hot water amount",
"parameterUnit": "min",
"writable": false,
"timestamp": "2026-05-24T17:15:00+00:00",
"value": 19.0,
"strVal": "19min",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "65535",
"parameterName": "Text not found: id[], fw[nibe-e10], lang[en-US]",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
}
]